Transmissometers
are instruments that measure the optical Transmittance of a test piece
over some specified range of wavelength. In general, these instruments
can perform at infrared, visible, or ultraviolet wavelengths, although
all wavelengths will not be suitable for any particular application.
The
test piece may be a small piece of glass, a film being vacuum coated, a
small vial of liquid, a large vat of liquid, or the atmosphere itself over
some specified distance -- perhaps a kilometer or more. So the term "Transmissometer"
does not offer many clues to the type of instrument required -- a Transmissometer
is truly an "application-driven" instrument.
|
Test Piece or Substrate
|
Transmissometer Type
|
Special Features
|
Small
sample of solid material
Glass, Plastic, Filter,
Film, etc.,
Measured in the atmosphere
Usually for QC application |
Bench
Type (self-contained optics)
Remote Head (special size
samples) Single or multiple wavelengths |
Compact
self-contained optics.
Remote head (special geometries)
Single or multiple wavelengths |
Moving
Web in the atmosphere
Typically for Process control
and QC |
Remote
Head configured to web size |
Custom
remote head with one or more channels to monitor transmittance across width
of web. |
Moving
Web in High Vacuum
TYpically for Process Control
and QC |
High Vacuum
Remote Head
configured to web size |
Custom
remote head configured for installation in High Vacuum chamber. Single
or multiple channels to monitor Transmittance of web during coating process. |
Liquid
samples in plastic, glass or fused silica cuvettes
Usually for laboratory environment |
Bench
Type (self-contained optics)
Remote Head (special size
samples) Single or multiple wavelengths |
Compact
self contained optics configured to adapt to cuvette type in use. |
| Liquid
samples in large vats or tanks |
Remote
Head configured for each particular application.
Single or multiple wavelengths |
Sealed
Remote head
Submersible in non-corrosive
liquids Configured for the application. |
| Gases
in long path vessel |
External head configured
to vessel |
Usually
in the near infrared
(700 to 1000 nM wavelength)
Critical components sealed
against corrosive gases. |
Atmosphere
over hundreds or thousands of meters.
Typically to measure air
quality or to detect smoke from forest fires. |
Remote
optical head usually single wavelength. |
Optical
head with remote corner cube reflector to make double pass through atmosphere. |
Graham
Optical Systems manufactures a wide range of transmissometers and can
configure one specially for your application. All of these instruments
perform in full ambient lighting conditions -- no need to make the measurements
in the dark. We can help with your selection of the appropriate Transmissometer
for your application.
Information
required when considering the purchase of a Transmissometer:
| Size
and shape of sample: |
Small
test coupon?
QC
testing of large format product?
Will
sample be brought to Transmissometer or will Transmissometer be taken to
sample? |
| Nature
of sample: |
Solid?
Liquid?
Gas?
Atmosphere?
Ocean
or lake? |
Wavelength(s)
required: |
Infrared?
(700 nM to 1000 nM)
Visible?
(400 nM to 700 nM)
Ultraviolet?
(240 nM to 400 nM) |
| Number
of Channels required: |
Single
Channel?
Two
Channels?
Multiple
Channels? |
| Number
of measurements required per hour: |
1
to 10 measurements per hour?
10
to 100 measurements per hour"
100
to 500 measurements per hour?
Continuous
monitoring? |
| Environment
in which Transmissometer will be used: |
Laboratory?
Manufacturing
plant?
High
Vacuum?
High
Atmospheric Pressure?
Outdoor
environment?
Hostile
environment?
Corrosive
Liquid environment?
Corrosive
gas environment? |
| Analog
data display: |
Data Logger?
Chart Recorder
Computer Monitor |
| Digital
Data
Display |
4-1/2
Digit LED Display?
4-1/2 Digit LCD Display?
3-1/2 Digit LCD Display? |
Some Standard Model Transmissometers manufactured by Graham Optical Systems
|
MODEL
|
FEATURES
|
BENEFITS
|
|
Model
100
|
White
Light source only
3-1/2 digit LCD Display
Accuracy +/- 0.1% |
Low
power consumption
Battery
Version Available (Model 100B)
Lowest
Cost Model |
|
Model
100V
|
White
light or specific wavelength
4-1/2
digit LED or LCD Display
Accuracy
+/- 0.02%
Analog
output |
Accepts
filter for any visible wavelength
Multiple
Channel versions available
Extra
digit gives higher accuracy
Connect
to data logger or chart recorder |
|
Model
100IR
|
Specific
infrared wavelengths
4-1/2
digit LED or LCD Display
Accuracy
+/- 0.02%
Analog
Output |
Customer
selected wavelength
Multiple
wavelength option
Analog
Output
Connect
to data logger or chart recorder |
|
Model
500W
|
Remote
Optical Head
Bench
Top or Rack Mount available
4-1/2
digit LED or LCD Display
Accuracy
+/-0.02%
Analog
Output |
Usable
for measuring moving web
Model
for use in high vacuum chamber
Submersible
remote heads available
Multiple
channels available
Connect
to data logger or chart recorder |
|
Model
1000C
|
Computerized
model
Bench
Top or Rack Mount
Onboard
or remote optical head
4-1/2
digit LED or LCD Display
Accuracy
+/-0.02% |
Turnkey
System
Data
Logging capability
Process
Control capability
Continuous
chart recording
Multiple
channels available |
For
Further Information, Prices, Delivery, call Gordon Graham today at
(818)
700-1263 or send an email to the address below.
GRAHAM OPTICAL
SYSTEMS, 9530 Topanga Canyon Blvd., Chatsworth,
CA 91311
Phone
(818) 700-1263 FAX (818) 700-1627
E-mail: techinfo@grahamoptical.com
Copyright
© 2008 Graham Optical Systems All Rights Reserved
This
page last updated June 24, 2008
|