Transmissometers are instruments that measure the optical Transmittance of a test piece over some specified range of wavelength.  In general, these instruments can perform at infrared, visible, or ultraviolet wavelengths, although all wavelengths will not be suitable for any particular application. 

The test piece may be a small piece of glass, a film being vacuum coated, a small vial of liquid, a large vat of liquid, or the atmosphere itself over some specified distance -- perhaps a kilometer or more. So the term "Transmissometer" does not offer many clues to the type of instrument required -- a Transmissometer is truly an "application-driven" instrument.
 
Test Piece or Substrate
Transmissometer Type
Special Features
Small sample of solid material
Glass, Plastic, Filter, Film, etc.,
Measured in the atmosphere
Usually for QC application
Bench Type (self-contained optics)
Remote Head (special size samples) Single or multiple wavelengths
Compact self-contained optics.
Remote head (special geometries)
Single or multiple wavelengths
Moving Web in the atmosphere
Typically for Process control and QC
Remote Head configured to web size Custom remote head with one or more channels to monitor transmittance across width of web.
Moving Web in High Vacuum
TYpically for Process Control and QC
High Vacuum Remote Head
configured to web size
Custom remote head configured for installation in High Vacuum chamber. Single or multiple channels to monitor Transmittance of web during coating process.
Liquid samples in plastic, glass or fused silica cuvettes
Usually for laboratory environment
Bench Type (self-contained optics)
Remote Head (special size samples) Single or multiple wavelengths
Compact self contained optics configured to adapt to cuvette type in use. 
Liquid samples in large vats or tanks Remote Head configured for each particular application.
Single or multiple wavelengths
Sealed Remote head 
Submersible in non-corrosive liquids Configured for the application. 
Gases in long path vessel
External head configured to vessel
Usually in the near infrared
(700 to 1000 nM wavelength)
Critical components sealed against corrosive gases.
Atmosphere over hundreds or thousands of meters.
Typically to measure air quality or to detect smoke from forest fires.
Remote optical head usually single wavelength. Optical head with remote corner cube reflector to make double pass through atmosphere.

Graham Optical Systems manufactures a wide range of transmissometers and can configure one specially for your application.  All of these instruments perform in full ambient lighting conditions -- no need to make the measurements in the dark. We can help with your selection of the appropriate Transmissometer for your application. 

Information required when considering the purchase of a Transmissometer:

Size and shape of sample:  Small test coupon? 
QC testing of large format product?
Will sample be brought to Transmissometer or will Transmissometer be taken to sample?
Nature of sample: Solid?
Liquid?
Gas?
Atmosphere? 
Ocean or lake?

Wavelength(s) required:
Infrared?   (700 nM to 1000 nM)
Visible?      (400 nM to 700 nM)
Ultraviolet?  (240 nM to 400 nM)
Number of Channels required: Single Channel?
Two Channels?
Multiple Channels?
Number of measurements required per hour: 1 to 10 measurements per hour?
10 to 100 measurements per hour"
100 to 500 measurements per hour?
Continuous monitoring?
Environment in which Transmissometer will be used: Laboratory?
Manufacturing plant?
High Vacuum?
High Atmospheric Pressure?
Outdoor environment?
Hostile environment?
Corrosive Liquid environment?
Corrosive gas environment?
Analog data display: Data Logger?
Chart Recorder
Computer Monitor
Digital Data Display 4-1/2 Digit LED Display?
4-1/2 Digit LCD Display?
3-1/2 Digit LCD Display?

             Some Standard Model Transmissometers manufactured by Graham Optical Systems 

MODEL
FEATURES
BENEFITS
Model 100
White Light source only

3-1/2 digit LCD Display 

Accuracy  +/- 0.1% 

Low power consumption

Battery Version Available (Model 100B)

Lowest Cost Model

Model 100V
White light or specific wavelength

4-1/2 digit LED or LCD Display 

Accuracy +/- 0.02%

Analog output

Accepts filter for any visible wavelength

Multiple Channel versions available

Extra digit gives higher accuracy

Connect to data logger or chart recorder

Model 100IR
Specific infrared wavelengths

4-1/2 digit LED or LCD Display

Accuracy +/- 0.02%

Analog Output

Customer selected wavelength

Multiple wavelength option

Analog Output

Connect to data logger or chart recorder

Model 500W
Remote Optical Head

Bench Top or Rack Mount available

4-1/2 digit LED or LCD Display

Accuracy +/-0.02%

Analog Output

Usable for measuring moving web

Model for use in high vacuum chamber

Submersible remote heads available

Multiple channels available

Connect to data logger or chart recorder

Model 1000C
Computerized model

Bench Top or Rack Mount

Onboard or remote optical head 

4-1/2 digit LED or LCD Display

Accuracy +/-0.02%

Turnkey System

Data Logging capability

Process Control capability

Continuous chart recording

Multiple channels available

For Further Information, Prices, Delivery, call Gordon Graham today at 
(818) 700-1263 or send an email to the address below.

GRAHAM OPTICAL SYSTEMS,  9530 Topanga Canyon Blvd.,  Chatsworth, CA 91311

Phone (818) 700-1263     FAX   (818) 700-1627     E-mail: techinfo@grahamoptical.com

Copyright © 2008 Graham Optical Systems  All Rights Reserved

This page last updated June 24, 2008